Your browser doesn't support javascript.
loading
[Intermittent ciliary block as a result of haemodialysis]. / Intermittierender ziliarer Block durch Hämodialyse.
Schäfer, H-G; Kaczmarek, K; Gockeln, R; Meyer, M W; Winter, R; Erb, C.
Afiliação
  • Schäfer HG; Augenklinik und Poliklinik, Medizinische Hochschule, Carl-Neuberg-Strasse 1, 30625 Hannover. schaefer.hans-gernot@mh-hannover.de
Ophthalmologe ; 103(3): 221-3, 2006 Mar.
Article em De | MEDLINE | ID: mdl-15995843
ABSTRACT
We report the case of a patient who experienced recurrent elevations of intraocular pressure during haemodialysis. We measured a rise in intraocular pressure of 10-12 mmHg after dialysis. The lens showed intumescence, and a ciliary block was detected by means of Orbscan II. Within 6 h findings had normalized. Changes in serum osmolarity due to haemodialysis may result in fluid shifts between different compartments. Decrease of serum osmolarity during dialysis may lead to lens swelling and thus cause a ciliary block. This may end with regression of the lens swelling.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Hipertensão Ocular / Corpo Ciliar / Diálise Renal Limite: Aged / Humans / Male Idioma: De Revista: Ophthalmologe Assunto da revista: OFTALMOLOGIA Ano de publicação: 2006 Tipo de documento: Article