ABSTRACT
Sirolimus-eluting stents (SESs) reduce restenosis compared with bare metal stents. Safety issues with drug-eluting stents are particularly important given concerns of possible increased thrombogenicity. Compared with heparin plus glycoprotein IIb/IIIa inhibitors, the direct thrombin inhibitor bivalirudin has been shown to reduce the risk of hemorrhagic complications in patients receiving bare metal stents, with similar efficacy in preventing ischemic complications. The safety and efficacy of percutaneous coronary intervention (PCI) with SESs and bivalirudin anticoagulation have not been prospectively studied. This prospective study performed at 9 United States hospitals evaluated 1,182 patients referred for PCI with SESs in whom the procedural anticoagulant was bivalirudin. Clopidogrel was administered before PCI in 79% of patients, and only 5.3% received procedural glycoprotein IIb/IIIa inhibitors. At 30 days, major adverse cardiac events occurred in 7.1% of patients, including 0.3% mortality, 4.4% myocardial infarction (defined as creatine kinase-MB >3x normal), 1.7% target vessel revascularization, and 0.6% stent thrombosis. Major bleeding occurred in only 0.8% of patients. Thus, use of bivalirudin as the procedural anticoagulant to support SES implantation in a "real world" population of patients undergoing PCI results in low rates of major adverse cardiac events, stent thrombosis, and major bleeding.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Angioplastia Coronária com Balão / Stents / Doença das Coronárias / Materiais Revestidos Biocompatíveis / Anticoagulantes Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Am J Cardiol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Angioplastia Coronária com Balão / Stents / Doença das Coronárias / Materiais Revestidos Biocompatíveis / Anticoagulantes Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Am J Cardiol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos