Electrochemical immunosensor for cholera toxin using liposomes and poly(3,4-ethylenedioxythiophene)-coated carbon nanotubes.
Viswanathan, Subramanian; Wu, Li-Chen; Huang, Ming-Ray; Ho, Ja-An Annie.
Afiliação
  • Viswanathan S; BioAnalytical Chemistry Laboratory, Department of Chemistry, National Tsing Hua University, Hsinchu, 300 Taiwan.
Anal Chem ; 78(4): 1115-21, 2006 Feb 15.
Article em En | MEDLINE | ID: mdl-16478102
A sensitive method for the detection of cholera toxin (CT) using an electrochemical immunosensor with liposomic magnification followed by adsorptive square-wave stripping voltammetry is described. Potassium ferrocyanide-encapsulated and ganglioside (GM1)-functionalized liposomes act as highly specific recognition labels for the amplified detection of cholera toxin. The sensing interface consists of monoclonal antibody against the B subunit of CT that is linked to poly(3,4-ethylenedioxythiophene) coated on Nafion-supported multiwalled carbon nanotube caste film on a glassy carbon electrode. The CT is detected by a "sandwich-type" assay on the electronic transducers, where the toxin is first bound to the anti-CT antibody and then to the GM1-functionalized liposome. The potassium ferrocyanide molecules are released from the bounded liposomes on the electrode by lyses with methanolic solution of Triton X-100. The released electroactive marker is measured by adsorptive square-wave stripping voltammetry. The sandwich assay provides the amplification route for the detection of the CT present in ultratrace levels. The calibration curve for CT had a linear range of 10(-14)-10(-7)g mL(-1). The detection limit of this immunosensor was 10(-16) g of cholera toxin (equivalent to 100 microL of 10(-15) g mL(-1)).
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Técnicas Biossensoriais / Toxina da Cólera / Compostos Bicíclicos Heterocíclicos com Pontes / Nanotubos de Carbono / Eletroquímica / Lipossomos / Anticorpos Idioma: En Revista: Anal Chem Ano de publicação: 2006 Tipo de documento: Article País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Técnicas Biossensoriais / Toxina da Cólera / Compostos Bicíclicos Heterocíclicos com Pontes / Nanotubos de Carbono / Eletroquímica / Lipossomos / Anticorpos Idioma: En Revista: Anal Chem Ano de publicação: 2006 Tipo de documento: Article País de publicação: Estados Unidos