Your browser doesn't support javascript.
loading
Fluorescent sensors for Hg(2+) in micelles: a new approach that transforms an ON-OFF into an OFF-ON response as a function of the lipophilicity of the receptor.
Pallavicini, Piersandro; Diaz-Fernandez, Yuri Antonio; Foti, Francesco; Mangano, Carlo; Patroni, Stefano.
Afiliação
  • Pallavicini P; Dipartimento di Chimica Generale, Università di Pavia via Taramelli, 12-27100 Pavia, Italy. psp@unipv.it
Chemistry ; 13(1): 178-87, 2007.
Article em En | MEDLINE | ID: mdl-17042048
ABSTRACT
A new approach to the use of micelles in the fluorescent sensing of metal cations is proposed and applied to the case of Hg(2+). We demonstrate how it is possible to transform a system from an ON-OFF to an OFF-ON sensor by changing the length of the chain used to lipophilise a ligand that resides inside TritonX-100 micelles together with pyrene as the fluorophore. Three tetrathia-monoaza macrocyclic ligands have been synthesised with the same ring but functionalised on the nitrogen atom with a methyl (C1-NS4), an n-butyl (C4-NS4) or an n-dodecyl (C12-NS4) chain. The three ligands have been fully characterised in water containing TritonX-100 micelles by means of potentiometric titrations and their apparent protonation and complexation constants with Hg(2+) were determined. On the basis of the distribution diagrams obtained, the more lipophilic C12-NS4 has been developed as an ON-OFF fluorescent sensor for mercury working at pH<4, in the absence of Hg(2+) the ligand is inside the micelles, protonated and non-quenching, while on addition of mercury the [C12-NS4Hg](2+) complex forms which remains inside the micelles and is quenching. On the other hand, the ligand of intermediate chain length, C4-NS4, can be used to obtain an OFF-ON sensor at 7.0<pH<9.5. In the absence of added metal at pH>7.0 the ligand is unprotonated, it stays inside the micelles and is quenching, while addition of Hg(2+) in the 7.0-9.5 pH range results in the formation of [C4-NS4Hg](2+), which is hydrophilic enough to leave the micelles and to be released into the bulk solution where it is no longer capable of quenching pyrene fluorescence. Additional studies on C1-NS4, C3-NS4 and C8-NS4 indicate that the optimal chain length to observe this OFF-ON behaviour is C(3)-C(4).
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Itália
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Itália