Catheter entrapment during balloon angioplasty in patient with in-stent restenosis: an unusual complication and its surgical management.
J Card Surg
; 22(2): 160-2, 2007.
Article
em En
| MEDLINE
| ID: mdl-17338758
Entrapment of coronary angioplasty hardware is one of the rare complications of percutaneous coronary artery interventions. We reported herein a case of 58-year-old man with an entrapped balloon catheter and guidewire within the right coronary artery during the application of a conventional balloon angioplasty for in-stent restenosis. Surgical removal of the entrapped balloon catheter and guidewire was performed successfully with a coronary artery bypass grafting to the affected vessel. The application of the balloon angioplasty for in-stent restenosis requires every caution against such type of complications.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Angioplastia Coronária com Balão
/
Stents
/
Reestenose Coronária
Tipo de estudo:
Etiology_studies
Limite:
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
J Card Surg
Assunto da revista:
CARDIOLOGIA
Ano de publicação:
2007
Tipo de documento:
Article
País de afiliação:
Turquia
País de publicação:
Estados Unidos