Prosthetic valve thrombosis with adequate anticoagulation.
Int J Cardiol ; 117(3): e90-1, 2007 May 02.
Article em En | MEDLINE | ID: mdl-17363094
We report the case of a 41-year-old woman who developed thrombosis of a CarboMedics prosthetic valve in the mitral position despite adequate anticoagulation. This report provides further supportive data to recently published studies suggesting an increased thrombogenicity of the CarboMedics prosthetic valve in the mitral position and it underscores the importance of conducting large prospective, randomized trials for further evaluation of the thromboembolic complications of this valve.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Próteses Valvulares Cardíacas / Valva Mitral / Anticoagulantes Tipo de estudo: Clinical_trials Limite: Adult / Female / Humans Idioma: En Revista: Int J Cardiol Ano de publicação: 2007 Tipo de documento: Article País de publicação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Próteses Valvulares Cardíacas / Valva Mitral / Anticoagulantes Tipo de estudo: Clinical_trials Limite: Adult / Female / Humans Idioma: En Revista: Int J Cardiol Ano de publicação: 2007 Tipo de documento: Article País de publicação: Holanda