Your browser doesn't support javascript.
loading
Respiratory biofeedback during CT-guided procedures.
Locklin, Julia K; Yanof, Jeff; Luk, Alfred; Varro, Zoltan; Patriciu, Alexandru; Wood, Bradford J.
Afiliação
  • Locklin JK; Diagnostic Radiology Department, National Institutes of Health, Clinical Center, Bethesda , Maryland 20892, USA. locklin.linj@cc.nih.gov
J Vasc Interv Radiol ; 18(6): 749-55, 2007 Jun.
Article em En | MEDLINE | ID: mdl-17538137
ABSTRACT

PURPOSE:

Respiratory motion can be a complicating factor during image-guided interventions. The ability to reproduce breath-holds may facilitate safer needle-based procedures. The purpose of this study was to evaluate if respiratory biofeedback decreased variability among breath-holds and if the signals from the respiratory bellows belt can be used to measure target motion. MATERIALS AND

METHODS:

In phase 1 of the study, a respiratory bellows belt was applied to patients before image-guided interventional procedures. Belt stretch from respiratory motion was converted into voltage readings and displayed on a monitor as biofeedback. Patients were asked to perform inspiratory, expiratory, and midcycle breath-holds with and without the biofeedback. The variability in voltage readings between breath-holds with and without biofeedback was compared. In phase 2, the respiratory bellows belt was used during computed tomography (CT)-guided procedures with the patients blinded to the biofeedback. Voltage readings and CT series numbers were recorded as patients were asked to hold their breath during scans. The variability of CT z-axis targets was compared with the variability of voltage readings.

RESULTS:

A significant decrease in variability was found during expiratory breath-holds (P = .0083) with trends toward significance with midcycle and inspiratory breath-holds. A positive correlation (Kendall tau = 0.5; P = .024) was shown between CT z-axis and belt stretch variability in subjects who received smaller doses of moderate sedation compared with those who received larger doses or general anesthesia.

CONCLUSIONS:

Biofeedback may help the patient to have a more consistent breath-hold. The belt could decrease the error and unpredictability from craniocaudal motion of targets during image-guided interventions.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Sinais Assistido por Computador / Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Mecânica Respiratória / Artefatos / Neoplasias Tipo de estudo: Clinical_trials / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Assunto da revista: ANGIOLOGIA / RADIOLOGIA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Sinais Assistido por Computador / Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Mecânica Respiratória / Artefatos / Neoplasias Tipo de estudo: Clinical_trials / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Assunto da revista: ANGIOLOGIA / RADIOLOGIA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Estados Unidos