Comparisons of air and liquid personal cooling for intermittent heavy work in moderate temperatures.
Am Ind Hyg Assoc J
; 52(9): 393-7, 1991 Sep.
Article
em En
| MEDLINE
| ID: mdl-1781443
Personal microenvironmental cooling has been used to enhance safety and extend the work capacity of laborers wearing protective clothing. Previous studies of air and liquid cooling have used either very low work rates or high environmental temperatures. Emergency work tasks frequently require high work rates and occur in moderate ambient temperatures. The purpose of this research was to examine the efficacy of intermittent personal cooling during rest and to compare liquid and air cooling systems in subjects engaged in hard work. Fourteen volunteers wearing chemical protective clothing performed treadmill walking at a metabolic rate of 430 W for 45 min followed by a 15-min rest at a wet-bulb globe temperature of 25 degrees C. During rest, volunteers received either no cooling, air cooling, or liquid cooling. Both cooling systems partially alleviated heat strain and increased work time with the air system offering slightly more effective cooling.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Temperatura Corporal
/
Água
/
Ar
/
Esforço Físico
Limite:
Adult
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Am Ind Hyg Assoc J
Ano de publicação:
1991
Tipo de documento:
Article
País de publicação:
Estados Unidos