Atrial entrapment of flow directed pulmonary artery catheter-a technique for non-surgical removal.
Vakamudi, M; Ramakrishnan, T V; Rao, S; Acharya, D; Kamat, V; Srinivasa, S K; Saldana, R; Balakrishnan, K R.
Afiliação
  • Vakamudi M; Departments of Anaesthesiology and Cardiac Surgery, Sri Ramachandra Medical College University Hospital, Porur, Chennai, India.
Ann Card Anaesth ; 1(1): 60-1, 1998 Jan.
Article em En | MEDLINE | ID: mdl-17827626
ABSTRACT
A 43 year old patient who underwent mitral valve replacement had pulmonary artery catheter inserted before induction of anaesthesia. The catheter could no be removed postoperatively by routine manoeuvres in the intensive care unit. Fluoroscopy in the cardiac catheterization revealed a straight course of the catheter indicating the probability of its inclusion in the left atrial suture line. The pulmonary artery catheter was successfully removed percutaneously in the cardiac catheterization laborartory. The procedure is described.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ann Card Anaesth Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Índia
Buscar no Google