Your browser doesn't support javascript.
loading
Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants?
Newhauser, Wayne D; Giebeler, Annelise; Langen, Katja M; Mirkovic, Dragan; Mohan, Radhe.
Afiliação
  • Newhauser WD; Department of Radiation Physics, University of Texas M D Anderson Cancer Center, Houston, TX 77030, USA. wnewhaus@mdanderson.org
Phys Med Biol ; 53(9): 2327-44, 2008 May 07.
Article em En | MEDLINE | ID: mdl-18421122
ABSTRACT
Treatment planning calculations for proton therapy require an accurate knowledge of radiological path length, or range, to the distal edge of the target volume. In most cases, the range may be calculated with sufficient accuracy using kilovoltage (kV) computed tomography (CT) images. However, metal implants such as hip prostheses can cause severe streak artifacts that lead to large uncertainties in proton range. The purposes of this study were to quantify streak-related range errors and to determine if they could be avoided by using artifact-free megavoltage (MV) CT images in treatment planning. Proton treatment plans were prepared for a rigid, heterogeneous phantom and for a prostate cancer patient with a metal hip prosthesis using corrected and uncorrected kVCT images alone, uncorrected MVCT images and a combination of registered MVCT and kVCT images (the hybrid approach). Streak-induced range errors of 5-12 mm were present in the uncorrected kVCT-based patient plan. Correcting the streaks by manually assigning estimated true Hounsfield units improved the range accuracy. In a rigid heterogeneous phantom, the implant-related range uncertainty was estimated at <3 mm for both the corrected kVCT-based plan and the uncorrected MVCT-based plan. The hybrid planning approach yielded the best overall result. In this approach, the kVCT images provided good delineation of soft tissues due to high-contrast resolution, and the streak-free MVCT images provided smaller range uncertainties because they did not require artifact correction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Tomografia Computadorizada por Raios X / Neoplasias Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Tomografia Computadorizada por Raios X / Neoplasias Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos