Your browser doesn't support javascript.
loading
Quantification of viable tumor microvascular characteristics by multispectral analysis.
Berry, Leanne R; Barck, Kai H; Go, Mary Ann; Ross, Jed; Wu, Xiumin; Williams, Simon P; Gogineni, Alvin; Cole, Mary J; Van Bruggen, Nicholas; Fuh, Germaine; Peale, Frank; Ferrara, Napoleone; Ross, Sarajane; Schwall, Ralph H; Carano, Richard A D.
Afiliação
  • Berry LR; Department of Translational Oncology, Genentech, 1 DNA Way, South San Francisco, CA 94080, USA.
Magn Reson Med ; 60(1): 64-72, 2008 Jul.
Article em En | MEDLINE | ID: mdl-18421695
Tumor heterogeneity complicates the quantification of tumor microvascular characteristics assessed by dynamic contrast-enhanced MRI (DCE-MRI). To address this issue a novel approach was developed that combines DCE-MRI with diffusion-based multispectral (MS) analysis to quantify the microvascular characteristics of specific tumor tissue populations. Diffusion-based MS segmentation (feature space: apparent diffusion coefficient, T(2) and proton density) was performed to identify tumor tissue populations and the DCE-MRI characteristics were determined for each tissue class. The ability of this MS DCE-MRI technique to detect microvascular changes due to treatment with an antibody (G6-31) to vascular endothelial growth factor-A (VEGF) was evaluated in a tumor xenograft mouse model. Anti-VEGF treatment resulted in a significant reduction in K(trans) for the MS viable tumor tissue class (-0.0034 +/- 0.0022 min(-1), P < 0.01) at 24 hr posttreatment that differ significantly from the change observed in the control group (0.0002 +/- 0.0025 min(-1)). Viable tumor K(trans) for the anti-VEGF group was also reduced 62% relative to the pretreatment values (P < 0.01). Necrotic tissue classes were found to add only noise to DCE-MRI estimates. This approach provides a means to measure physiological parameters within the viable tumor and address the issue of tumor heterogeneity that complicates DCE-MRI analysis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Neoplasias Experimentais Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Neoplasias Experimentais Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos