Microtensile bond strength of adhesive systems to dentin with or without application of an intermediate flowable resin layer.
Braz Dent J
; 19(1): 51-6, 2008.
Article
em En
| MEDLINE
| ID: mdl-18438560
This study evaluated the effect of flowable composite resin application on the microtensile bond strength (microTBS) of adhesive systems to dentin. Occlusal surfaces of human third molars were ground to obtain flat dentin surfaces. The crown of each tooth was sectioned occluso-gingivally into four quarters with a water-cooled diamond saw. One of the following adhesive systems was applied to dentin surface in each quarter of the same tooth, following manufacturers' instructions: Scotchbond Multipurpose, Single Bond Adper Prompt and Clearfil SE Bond. Experimental and control groups received the same treatment, except for the fact that a layer of flowable composite (Filtek Flow) was placed and light-cured on top of the adhesive layer in the specimens of the experimental groups. Resin composite (Filtek Z250) crown buildups were then made on the bonded surfaces and incrementally light-cured for 20 s. The restored teeth were stored in water at 37 degrees C for 24 h. Each tooth quarter was serially cut in a longitudinal direction in order to obtain several bonded sticks (0.9-mm(2) in cross-section). Maximal microtensile stress (in MPa) at failure was recorded using a universal testing machine. Data were analyzed by two-way ANOVA and Tukey's test at 5% significance level. Placement of a low-viscosity resin to the hybridized dentin increased the microTBS for all tested adhesive systems. However, such increase was significant only for Clearfil SE Bond (p<0.05). When the restorations were placed without low-viscosity resin, Clearfil SE Bond presented higher microTBS than Adper Prompt (p<0.05). For the groups treated with flowable composite, Clearfil SE Bond produced the highest microTBS means to dentin. In conclusion, the effect of the addition of an intermediate flowable composite layer on microTBS to dentin was material-dependent and resulted in an increased adhesion for all tested materials, though with significance only for Clearfil SE Bond.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Colagem Dentária
/
Adesivos Dentinários
/
Resinas Compostas
/
Materiais Dentários
/
Dentina
Tipo de estudo:
Clinical_trials
Limite:
Humans
Idioma:
En
Revista:
Braz Dent J
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2008
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil