ABSTRACT

PURPOSE:

Dynamic liver MRI images have been obtained under expiration breath holding (BH). However, problems with obtaining reproducible liver positions often observed. This study investigated ways to improve the reproducibility of liver position on dynamic liver MRI. MATERIALS AND

METHODS:

After giving informed consent, 60 patients (32 males and 28 females, ages 33-85, median age 69) were examined by liver dynamic MRI under two types of BH. The BH phases were voluntary expiration (VE) phase without any explanations and functional residual capacity (FRC) phase after careful explanation was provided. Plain images, arterial phase images, portal phase images and parenchymal phase images were obtained. For statistical evaluation of reproducibility, the area of the 2nd or 3rd images from top of the liver was measured in each phase using a threshold value of half maximum. Misregistration areas were calculated by finding the remainder of the liver area in the plain-arterial (Pl-A) phase, arterial-portal (A-Po) phase, plain-parenchymal (Pl-Pa) phase. Contingency table analysis was done due to the misregistration was occurred or not.

RESULTS:

Misregistration of liver image on the VE and the FRC of three phase types were statistical significant on the Pl-A (p < 0.01), on the A-Po (p < 0.01) and on the Pl-Pa (p < 0.05), respectively.

CONCLUSION:

The FRC phase following careful explanation of the BH provided significantly improved reproducibility of liver position on dynamic liver MRI. Therefore, precise subtraction images could be obtained for routine clinical examinations without slice matching.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Fígado Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: Ja Revista: Nihon Hoshasen Gijutsu Gakkai Zasshi Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Japão
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Fígado Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: Ja Revista: Nihon Hoshasen Gijutsu Gakkai Zasshi Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Japão
...