Your browser doesn't support javascript.
loading
A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies.
Zhou, Yun; Ye, Weiguo; Brasic, James R; Crabb, Andrew H; Hilton, John; Wong, Dean F.
Afiliação
  • Zhou Y; The Russell H Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, Maryland 21287, USA. yunzhou@jhmi.edu
Neuroimage ; 44(3): 661-70, 2009 Feb 01.
Article em En | MEDLINE | ID: mdl-18930830
The widely used Logan plot in radioligand receptor dynamic PET studies produces marked noise-induced negative biases in the estimates of total distribution volume (DV(T)) and binding potential (BP). To avoid the inconsistencies in the estimates from the Logan plot, a new graphical analysis method was proposed and characterized in this study. The new plot with plasma input and with reference tissue input was first derived to estimate DV(T) and BP. A condition was provided to ensure that the estimate from the new plot equals DV(T) or BP. It was demonstrated theoretically that 1) the statistical expectations of the estimates from the new plot with given input are independent of the noise of the target tissue concentration measured by PET; and 2) the estimates from the time activity curves of regions of interest are identical to those from the parametric images for the new plot. The theoretical results of the new plot were also confirmed by computer simulations and fifty-five human [(11)C]raclopride dynamic PET studies. By contrast, the marked noise-induced underestimation in the DV(T) and BP images and noise-induced negative bias in the estimates from the Logan plot were demonstrated by the same data sets used for the new plot. The computational time for generating DV(T) or BP images in the human studies was reduced by 80% on average by the new plot in contrast to the Logan plot. In conclusion, the new plot is a consistent and computationally efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Racloprida / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Racloprida / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos