Your browser doesn't support javascript.
loading
Negative APCI-LC/MS/MS method for determination of natural persistent halogenated products in marine biota.
Haraguchi, Koichi; Kato, Yoshihisa; Atobe, Kazutaka; Okada, Syohei; Endo, Tetsuya; Matsubara, Futoshi; Oguma, Takayoshi.
Afiliação
  • Haraguchi K; Daiichi College of Pharmaceutical Sciences, 22-1 Tamagawa-cho, Minami-ku, Fukuoka 815-8511, Japan. k-haraguti@daiichi-cps.ac.jp
Anal Chem ; 80(24): 9748-55, 2008 Dec 15.
Article em En | MEDLINE | ID: mdl-19012416
A sensitive and selective method utilizing high performance liquid chromatography coupled to negative atmospheric pressure chemical ionization tandem mass spectrometry (APCI-LC/MS/MS) was developed to enable analysis of selected natural persistent organohalogens accumulated in marine biota. The analytes were three methoxylated tetrabromodiphenyl ethers (6-MeO-BDE47, 2'-MeO-BDE68, and 2',6-diMeO-BDE68), a dimethoxylated tetrabromobiphenyl (2,2'-diMeO-BB80), and two halogenated methyl bipyrroles (Cl(7)-MBP and Br(4)Cl(2)-DBP). These products were well resolved on a 150 mm reversed-phase column with methanol as the mobile phase. The fragmentation pathways of the Cl(7)-MBP and Br(4)Cl(2)-DBP produced characteristic multiple reaction monitoring (MRM) transitions. Determination was performed in the MRM mode using phenoxide ion [M-Br+O](-) and product Br(-) ions for MeO-BDE analogues, or the precursor [M-Cl+O](-) to Br(-) ion for Br(4)Cl(2)-DBP, and to C(4)NCl(4)(-) ion for Cl(7)-MBP. The APCI-LC/MS/MS method is acceptable for calibration of the linearity and repeatability of all products studied in the low ng/g (lipid weight) level and with similar sensitivity to the electron ionization (EI)-GC/MS method. The proposed method was applied for quantification of natural organohalogens accumulated in melon-headed whale (Peponocephala electra) blubber (N = 15) in the Asia-Pacific Ocean. The concentration was positively correlated between different groups of compounds except for 2'-MeO-BDE68. The use of the analytical method based on negative ion APCI-LC/MS/MS would provide a new way for rapid monitoring of halogenated natural products from marine biota, such as sponges or algae.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Baleias / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Espectrometria de Massas em Tandem / Éteres Difenil Halogenados / Halogênios Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Baleias / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Espectrometria de Massas em Tandem / Éteres Difenil Halogenados / Halogênios Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos