Reliability of rehabilitative ultrasound imaging of the transversus abdominis and lumbar multifidus muscles.
Koppenhaver, Shane L; Hebert, Jeffrey J; Fritz, Julie M; Parent, Eric C; Teyhen, Deydre S; Magel, John S.
Afiliação
  • Koppenhaver SL; College of Health, University of Utah, Salt Lake City, UT, USA. shanekoppenhaver@mac.com
Arch Phys Med Rehabil ; 90(1): 87-94, 2009 Jan.
Article em En | MEDLINE | ID: mdl-19154834
ABSTRACT

OBJECTIVES:

To evaluate the intraexaminer and interexaminer reliability of rehabilitative ultrasound imaging (RUSI) in obtaining thickness measurements of the transversus abdominis (TrA) and lumbar multifidus muscles at rest and during contractions.

DESIGN:

Single-group repeated-measures reliability study.

SETTING:

University and orthopedic physical therapy clinic.

PARTICIPANTS:

A volunteer sample of adults (N=30) with current nonspecific low back pain (LBP) was examined by 2 clinicians with minimal RUSI experience.

INTERVENTIONS:

Not applicable. MAIN OUTCOME

MEASURES:

Thickness measurements of the TrA and lumbar multifidus muscles at rest and during contractions were obtained by using RUSI during 2 sessions 1 to 3 days apart. Percent thickness change was calculated as thickness(contracted)-thickness(rest)/thickness(rest). Intraclass correlation coefficients (ICC) were used to estimate reliability.

RESULTS:

By using the mean of 2 measures, intraexaminer reliability point estimates (ICC(3,2)) ranged from 0.96 to 0.99 for same-day comparisons and from 0.87 to 0.98 for between-day comparisons. Interexaminer reliability estimates (ICC(2,2)) ranged from 0.88 to 0.94 for within-day comparisons and from 0.80 to 0.92 for between-day comparisons. Reliability estimates comparing measurements by the 2 examiners of the same image (ICC(2,2)) ranged from 0.96 to 0.98. Reliability estimates were lower for percent thickness change measures than the corresponding single thickness measures for all conditions.

CONCLUSIONS:

RUSI thickness measurements of the TrA and lumbar multifidus muscles in patients with LBP, when based on the mean of 2 measures, are highly reliable when taken by a single examiner and adequately reliable when taken by different examiners.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dor Lombar / Músculos Abdominais / Contração Muscular Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Arch Phys Med Rehabil Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dor Lombar / Músculos Abdominais / Contração Muscular Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Arch Phys Med Rehabil Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos