Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma.
Morita, Tetsuya; Shoji, Nobuyuki; Kamiya, Kazutaka; Hagishima, Mana; Fujimura, Fusako; Shimizu, Kimiya.
Afiliação
  • Morita T; Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Sagamihara, Kanagawa 228-8555, Japan. tamorin@dj.mbn.or.jp
Graefes Arch Clin Exp Ophthalmol ; 248(1): 73-7, 2010 Jan.
Article em En | MEDLINE | ID: mdl-19693527
BACKGROUND: To investigate intraocular pressure (IOP) measurement values in normal tension glaucoma (NTG) eyes using two different types of tonometer that are supposed to be little affected by corneal biochemical properties. METHODS: This study included 30 normal eyes of 16 healthy subjects and 30 eyes of 16 patients with NTG. IOP was measured with a Goldmann applanation tonometer (GAT), a Pascal dynamic contour tonometer (DCT), and a Reichert ocular response analyzer (ORA) three times each for normal and NTG eyes. The main measures were GAT-IOP, DCT-IOP, corneal-compensated IOP (IOPcc), Goldmann-correlated IOP (IOPg), and central corneal thickness (CCT). RESULTS: In normal eyes, GAT-IOP was 13.2 +/- 1.4 mmHg; DCT-IOP, 13.0 +/- 1.6 mmHg; IOPcc, 13.6 +/- 2.0 mmHg; and IOPg, 12.4 +/- 2.0 mmHg. Multivariate analysis revealed no significant differences between the four measurements (p = 0.08). CCT was 524.6 +/- 27.3 microns. In NTG eyes, GAT-IOP was 13.1 +/- 1.3 mmHg; DCT-IOP, 13.7 +/- 1.3 mmHg; IOPcc, 15.2 +/- 2.0 mmHg; and IOPg, 12.7 +/- 2.0 mmHg. Multivariate analysis showed significant differences between the four measurements (p < 0.01). Sheffé's test showed that IOPcc was significantly higher than GAT-IOP, DCT-IOP, and IOPg (GAT-IOP vs IOPcc: p < 0.0001; DCT-IOP vs IOPcc: p = 0.01; IOPcc vs IOPg: p < 0.0001). CCT was 515.4 +/- 32.9 microns, with no significant difference between normal and NTG eyes (p = 0.15). CONCLUSIONS: We investigated the values of IOP in NTG eyes as measured by the DCT and ORA. IOPcc was significantly greater than GAT-IOP, DCT-IOP and IOPg in NTG eyes, suggesting the possibility that IOP values may be underestimated.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Glaucoma de Ângulo Aberto / Pressão Intraocular Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Japão País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Glaucoma de Ângulo Aberto / Pressão Intraocular Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Japão País de publicação: Alemanha