Extending the use of "Inverted Chirality Columns Approach" for enantiomeric excess determination in absence of reference samples: Application to a water-soluble camptothecin derivative.
Badaloni, Elena; Cabri, Walter; Ciogli, Alessia; D'Acquarica, Ilaria; Deias, Roberto; Gasparrini, Francesco; Giorgi, Fabrizio; Kotoni, Dorina; Villani, Claudio.
Afiliação
  • Badaloni E; Analytical Development, R&D Department, sigma-tau S.p.A., Via Pontina km 30,400, 00040 Pomezia, Italy.
J Chromatogr A ; 1217(7): 1024-32, 2010 Feb 12.
Article em En | MEDLINE | ID: mdl-19863967
The aim of the present study was to extend the use of the "Inverted Chirality Columns Approach (ICCA)" previously developed for the identification and quantitation of the trace enantiomer in highly enriched samples of the camptothecin (CPT) family of drugs to a novel water-soluble CPT derivative, namely namitecan (ST1968), currently undergoing phase I clinical trials as anticancer agent. Namitecan, identified from a series of hydrophilic 7-oxyiminomethyl derivatives, contains a free terminal amino group, which traditionally hampers the analysis under normal-phase HPLC conditions. Nevertheless, commercially available Pirkle-type chiral stationary phases (CSPs) available in both the enantiomeric forms (i.e., having the same bound selector with opposite configuration) mainly operate under normal-phase HPLC conditions. For this reason, namitecan was pre-column N-protected with isocyanates A-D and their sulfur analogues E-H to reduce its polarity by converting the amino group into a fragment compatible with the chiral recognition mechanism (i.e., ureido and thioureido groups). Once the optimal columns system and derivatizing agents were selected, an original enantioselective HPLC-MS/MS technique was developed on the Whelk-O1 CSPs.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Camptotecina / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Idioma: En Revista: J Chromatogr A Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Itália País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Camptotecina / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Idioma: En Revista: J Chromatogr A Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Itália País de publicação: Holanda