Your browser doesn't support javascript.
loading
Hinged total knee arthroplasty in the presence of ligamentous deficiency.
Hernández-Vaquero, Daniel; Sandoval-García, Manuel A.
Afiliação
  • Hernández-Vaquero D; Department of Orthopaedic Surgery, School of Medicine, University of Oviedo, Oviedo, Spain. dhernandezv@meditex.es
Clin Orthop Relat Res ; 468(5): 1248-53, 2010 May.
Article em En | MEDLINE | ID: mdl-20087700
BACKGROUND: Rotating-hinge total knee prostheses may be used for the treatment of global instability about the knee. The designs of previous generations were associated with suboptimal outcomes. QUESTIONS/PURPOSES: We evaluated the clinical and radiographic outcomes of salvage knee reconstructions using modern-generation, modular, kinematic rotating-hinge total knee prostheses. METHODS: We retrospectively reviewed 26 rotating-hinge arthroplasty devices to examine whether acceptable results were obtainable using a single arthroplasty design. The average age of the patients was 77 years (SD, 9 years); the minimum followup was 24 months (mean, 46 months; range, 24-107 months). The indication was revision surgery in 21 patients and complex primary surgery in five. Patients were evaluated clinically (Knee Society score) and radiographically (positions of components, signs of loosening, bone loss). RESULTS: Knee Society pain scores improved from 40 preoperatively to 77 postoperatively, and function scores improved from 36 to 51. ROM improved from -15 masculine to -10 masculine. None of the patients' knee pain or function worsened. No loosening of implants was observed. Nonprogressive radiolucent lines were identified around the femoral and tibial components in three knees. Three patients required reoperations: one showed a supracondylar periprosthetic fracture treated by open reduction and internal fixation, whereas the other two had periprosthetic infections. CONCLUSIONS: Reconstruction with rotating-hinge total knee prostheses can provide substantial improvement in function and a reduction in pain in extreme circumstances, such as gross instability. We believe this salvage procedure should be reserved for severe ligamentous deficiencies in elderly and sedentary patients or whenever revision surgery techniques fail. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligamento Colateral Médio do Joelho / Artroplastia do Joelho / Instabilidade Articular Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Clin Orthop Relat Res Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Espanha País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligamento Colateral Médio do Joelho / Artroplastia do Joelho / Instabilidade Articular Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Clin Orthop Relat Res Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Espanha País de publicação: Estados Unidos