Your browser doesn't support javascript.
loading
Endovascular graft deployment in the false lumen of type B dissection.
Follis, Fabrizio; Filippone, Gianfranco; Stabile, Amerigo; Montalbano, Giuseppe; Floriano, Maria; Finazzo, Mario; Follis, Marco.
Afiliação
  • Follis F; Department of Cardiac Surgery, ARNAS, Palermo, Italy. follis99@hotmail.com
Interact Cardiovasc Thorac Surg ; 10(4): 597-9, 2010 Apr.
Article em En | MEDLINE | ID: mdl-20118121
ABSTRACT

OBJECTIVES:

Thoracic endovascular aortic repair (TEVAR) is particularly indicated in a patient with complicated type B dissection. The object of this communication is to report a case of deployment of the endograft in the false lumen, to propose a protocol in order to prevent it and discuss the possible surgical options when this complication has occurred.

METHODS:

A case of complicated acute type B dissection is described where the endovascular prosthesis was positioned in the false lumen. The literature on the subject is briefly reviewed for the insertion techniques and conversion to surgery.

RESULTS:

The occurrence was recognized and treated with replacement of the entire aorta from the sinotubular junction to a level of the eighth thoracic vertebra under deep circulatory arrest with selective antegrade cerebral perfusion.

CONCLUSIONS:

TEVAR for complicated type B dissection should be carried out according to a precise and stepwise protocol in institutions familiar with all the different options of conversion to open repair.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Dissecção Aórtica Limite: Humans / Male / Middle aged Idioma: En Revista: Interact Cardiovasc Thorac Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Dissecção Aórtica Limite: Humans / Male / Middle aged Idioma: En Revista: Interact Cardiovasc Thorac Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Itália