ABSTRACT

PURPOSE:

The aim of the present paper was to determine the effect of different types of ionizing radiation on the bond strength of three different dentin adhesive systems. MATERIALS AND

METHODS:

One hundred twenty specimens of 60 human teeth (protocol number 032/2007) sectioned mesiodistally were divided into 3 groups according to the adhesives systems used SB (Adper Single Bond Plus), CB (Clearfil SE Bond) and AP (Adper Prompt Self-Etch). The adhesives were applied on dentin and photo-activated using LED (Lec 1000, MMoptics, 1000 mW/cm2). Customized elastomer molds (0.5 mm thickness) with three orifices of 1.2 mm diameter were placed onto the bonding areas and filled with composite resin (Filtek Z-250), which was photo-activated for 20 s. Each group was subdivided into 4 subgroups for application of the different types of ionizing radiation ultraviolet radiation (UV), diagnostic x-ray radiation (DX), therapeutic x-ray radiation (TX) and without irradiation (control group, CG). Microshear tests were carried out (Instron, model 4411), and afterwards the modes of failure were evaluated by optical and scanning electron microscope and classified using 5 scores adhesive failure, mixed failures with 3 significance levels, and cohesive failure. The results of the shear bond strength test were submitted to ANOVA with Tukey's test and Dunnett's test, and the data from the failure pattern evaluation were analyzed with the Mann Whitney test (p = 0.05).

RESULTS:

No change in bond strength of CB and AP was observed after application of the different radiation types, only SB showed increase in bond strength after UV (p = 0.0267) irradiation. The UV also changed the failure patterns of SB (p = 0.0001).

CONCLUSION:

The radio-induced changes did not cause degradation of the restorations, which means that they can be exposed to these types of ionizing radiation without weakening the bond strength.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colagem Dentária / Adesivos Dentinários / Cimentos de Resina Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: J Adhes Dent Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colagem Dentária / Adesivos Dentinários / Cimentos de Resina Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: J Adhes Dent Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil