Quantification, confirmation and screening capability of UHPLC coupled to triple quadrupole and hybrid quadrupole time-of-flight mass spectrometry in pesticide residue analysis.
Grimalt, Susana; Sancho, Juan V; Pozo, Oscar J; Hernández, Félix.
Afiliação
  • Grimalt S; Research Institute for Pesticides and Water, University Jaume I, E-12071 Castellón, Spain.
J Mass Spectrom ; 45(4): 421-36, 2010 Apr.
Article em En | MEDLINE | ID: mdl-20301091
ABSTRACT
The potential of three mass spectrometry (MS) analyzers (triple quadrupole, QqQ; time of flight, TOF; and quadrupole time of flight, QTOF) has been investigated and compared for quantification, confirmation and screening purposes in pesticide residue analysis of fruit and vegetable samples. For this purpose, analytical methodology for multiresidue determination of 11 pesticides, taken as a model, has been developed and validated in nine food matrices for the three mass analyzers coupled to ultra high pressure liquid chromatography. In all cases, limits of quantification around 0.01 mg/kg were reached, fulfilling the most restrictive case of baby-food analysis. Regarding absolute sensitivity, the lower limits of detection were obtained, as expected, for QqQ (100 fg), whereas slightly higher limits (300 fg) were obtained for both TOF and QTOF. Confirmative capacity of each analyzer was studied for each analyte based on the identification points (IPs) criterion, useful for a comprehensive comparison. QTOF mass analyzer showed the highest confirmatory capacity, although QqQ normally led to sufficient number of IPs, even at lower concentration levels. The potential of TOF MS was also investigated for screening purposes. To this aim, around 50 commercial fruits and vegetables samples were analyzed, searching for more than 400 pesticides. TOF MS proved to be an attractive analytical tool for rapid detection and reliable identification of a large number of pesticides thanks to the full spectrum acquisition at accurate mass with satisfactory sensitivity. This process is readily boosted when combined with specialized software packages, together with theoretical exact mass databases. Several pesticides (e.g. carbendazim in citrus and indoxacarb in grape) were detected in the samples. Further unequivocal confirmation of the identity was performed using reference standards and/or QTOF MS/MS experiments.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Resíduos de Praguicidas / Cromatografia Líquida de Alta Pressão / Análise de Alimentos Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Idioma: En Revista: J Mass Spectrom Assunto da revista: BIOQUIMICA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Resíduos de Praguicidas / Cromatografia Líquida de Alta Pressão / Análise de Alimentos Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Idioma: En Revista: J Mass Spectrom Assunto da revista: BIOQUIMICA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Espanha