Your browser doesn't support javascript.
loading
Up to 6-year follow-up after pulmonary vein isolation for persistent/permanent atrial fibrillation: importance of sinus node function.
Soga, Yoshiharu; Okabayashi, Hitoshi; Arai, Yoshio; Nomoto, Takuya; Nakano, Jota; Matsuo, Takehiko; Hanyu, Michiya.
Afiliação
  • Soga Y; Department of Cardiovascular Surgery, Nara Hospital, Kinki University School of Medicine, Ikoma, Nara, Japan. sogakin@dd.iij4u.or.jp
J Thorac Cardiovasc Surg ; 141(6): 1455-60, 2011 Jun.
Article em En | MEDLINE | ID: mdl-20832828
OBJECTIVE: Sinus node dysfunction is commonly associated with atrial fibrillation. There is little information about the long-term results of pulmonary vein isolation in relation to sinus node function. The present study was conducted to investigate whether sinus node dysfunction affects the late outcome of pulmonary vein isolation in patients with persistent/permanent atrial fibrillation. METHODS: Among 76 consecutive patients with persistent/permanent atrial fibrillation who had undergone cut-and-sew pulmonary vein isolation, 66 patients without evidence of intra-atrial thrombus by transesophageal echography, and who were able to tolerate cardioversion, were enrolled. Sinus node recovery time after cardioversion was examined intraoperatively. All of the patients underwent valvular surgery concomitantly (mitral in 62). RESULTS: Sinus node dysfunction was detected in 18 patients. These patients had a significantly lower f wave voltage in V(1) of the electrocardiogram and a larger cardiothoracic ratio than patients with normal sinus node function. Hospital mortality was 3%, and 3 late deaths were observed. Follow-up was conducted for up to 72 months (mean 30 months), with a 100% complete follow-up rate. There were no significant differences in actuarial survival and freedom from cardiac events between patients with normal and abnormal sinus node function. No thromboembolic events occurred. A significantly higher proportion of patients with normal sinus node function (82%) were free of atrial fibrillation at 4 years than patients with sinus node dysfunction (25%; P < .0001). CONCLUSIONS: The atrial fibrillation cure rate after pulmonary vein isolation may be influenced by sinus node function in both the early and late stages. Although further examinations are required, pulmonary vein isolation may be an adequate treatment for persistent/permanent atrial fibrillation in patients with normal sinus node function.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Síndrome do Nó Sinusal / Criocirurgia Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: J Thorac Cardiovasc Surg Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Síndrome do Nó Sinusal / Criocirurgia Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: J Thorac Cardiovasc Surg Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos