Effects of the radiofrequency interference with modified titanium surgical clips on liver parenchyma--an in vivo experiment.
Gonganau-Nitu, D; Scurtu, R R; Precup, C G; Dindelegan, G; Biro, A; Crisan, C; Cocu, S; Popa, C; Ciuce, C.
Afiliação
  • Gonganau-Nitu D; Department of Surgery No 1, University of Medicine and Pharmacy Iuliu Hatieganu Cluj-Napoca, Romania Technical University, Cluj-Napoca, Romania.
Chirurgia (Bucur) ; 105(4): 501-8, 2010.
Article em En | MEDLINE | ID: mdl-20941972
AIM: This study sets out to test the biocompatibility of titanium clips in liver, in the presence of radiofrequency. Biocompatibility is assessed at various distances from the RF electrode and different points in time. METHOD: It is an experimental study conducted on pigs and makes use of histological changes that occur at the liver-titanium interface in presence of RF to test hypotheses. The titanium clips were modified in high vacuum (10 -5 atm) by heating them at 1000 degrees C and 1150 degrees C. Titanium clips were placed in liver at 0.5, 1.5 and 2.5 cm from RF probe. At 7, 14 and 28 days the inflammation, necrosis and fibrosis were assessed. RESULTS: The histological alterations decrease with the distance of implantation of titanium clips. The inflammation and necrosis nearby the titanium clips decrease in time, but the fibrosis does not increased, as expected. The modified titanium at 1000 degrees C clips cause less necrosis than commercial titanium clips. The moderator role of clip type between distance and cell alteration is empirically supported only for fibrosis and necrosis. The moderator role between time and cell alteration is supported only for inflammation. CONCLUSIONS: Experimental data suggests there are no preferred surgical clips in all situations. The biocompatibility of the titanium clips depends on the distance from the RF probe. The commercial ones prove less damaging if they are placed close to the RF probe (less than 1 cm) and those that were treated at 1150 C have a better bio-compatibility if placed more than 1 cm from RF probe.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Instrumentos Cirúrgicos / Titânio / Teste de Materiais / Ablação por Cateter / Hepatectomia / Fígado Limite: Animals Idioma: En Revista: Chirurgia (Bucur) Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Romênia País de publicação: Romênia
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Instrumentos Cirúrgicos / Titânio / Teste de Materiais / Ablação por Cateter / Hepatectomia / Fígado Limite: Animals Idioma: En Revista: Chirurgia (Bucur) Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Romênia País de publicação: Romênia