Your browser doesn't support javascript.
loading
In vivo study comparing an X-shaped polymethylmethacrylate and a cylindrical collagen implant for deep sclerectomy.
Codreanu, Andrea; Tran, Hoai V; Wiaux, Christophe; Mansouri, Kaweh; Roy, Sylvain; Mermoud, Andre; Schnyder, Corinne.
Afiliação
  • Codreanu A; Glaucoma Unit, Jules Gonin Eye Hospital, University of Lausanne, Lausanne, Switzerland.
Clin Exp Ophthalmol ; 39(2): 135-41, 2011 Mar.
Article em En | MEDLINE | ID: mdl-20973889
BACKGROUND: Study in vivo characteristics of a polymethylmethacrylate (PMMA) implant compared to the standard cylindrical collagen implant for deep sclerectomy (DS). DESIGN: Six-month comparative study. SAMPLES: Twenty eyes of ten rabbits. METHODS: Eyes were randomized to have DS with PMMA implant in one eye and collagen implant in the opposite eye. The growth of the new subconjunctival drainage vessels was assessed by combined fluorescein and indocyanin green anterior segment angiography; intrascleral and subconjunctival blebs were imaged by ultrasound biomicroscopy (UBM). At six months, outflow facility (C) was measured by anterior chamber perfusion and portions of one side of the DS were compared to portions on the 180° opposite side and native sclera on histology. RESULTS: The mean IOP preoperatively and at one, four, twelve, and twenty-four weeks was comparable in both groups (P > 0.1). UBM showed a statistically insignificant quicker regression of the subconjunctival bleb as well as a durable intrascleral lake in the PMMA group (P > 0.05). New drainage vessels were initially observed one month after surgery; they were more numerous in the PMMA group on angiographic and histological findings at 6 months (P < 0.05). The mean C increased significantly after surgery compared to preoperative values (P < 0.05) and no difference was observed between the implants (0.24 ± 0.06 µl/min/mmHg [PMMA] and 0.23 ± 0.07 µl/min/mmHg [collagen implant]) (P = 0.39). CONCLUSIONS: Deep sclerectomy performed with PMMA or collagen implants showed similar IOP lowering effects, outflow facility increase, and degree of inflammatory reaction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Esclera / Esclerostomia / Colágeno / Polimetil Metacrilato Limite: Animals Idioma: En Revista: Clin Exp Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Suíça País de publicação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Esclera / Esclerostomia / Colágeno / Polimetil Metacrilato Limite: Animals Idioma: En Revista: Clin Exp Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Suíça País de publicação: Austrália