Minimum detectable annual dose calculation for routine individual monitoring programme in case of plutonium and uranium contamination of the workplace.
Radiat Prot Dosimetry
; 144(1-4): 419-22, 2011 Mar.
Article
em En
| MEDLINE
| ID: mdl-21068022
An example of a numerical method application for minimum detectable annual dose calculation that can be guaranteed by the operating monitoring programmes for plutonium and uranium is presented. The method analyses the frequency distribution for a total number of counts obtained in n measurements performed during n monitoring intervals that are inside the calendar year. Urine sample radiometric measurement technique for plutonium and uranium operating monitoring programmes is investigated, showing dependences of the detection limits on the frequency of measurements, on number of calendar years under observation and on the activity median aerodynamic diameter (AMAD). Only a probability density function (PDF), for the background number of counts, stochastic variability of urine excretion and uncertainty of the intake pattern were taken into account as the main variables influencing the calculated detection limits. But there is no limitation for the proposed method to include the variability of other influencing model parameters in the calculation procedure.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Proteção Radiológica
/
Radiometria
/
Monitoramento de Radiação
/
Exposição Ocupacional
/
Plutônio
/
Urânio
Tipo de estudo:
Health_economic_evaluation
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
Radiat Prot Dosimetry
Ano de publicação:
2011
Tipo de documento:
Article
País de publicação:
Reino Unido