Determinants of blood flow and ultrafiltration in continuous arteriovenous haemodiafiltration: theoretical predictions and laboratory and clinical observations.
Vincent, H H; Akçahuseyin, E; Vos, M C; van Ittersum, F J; van Duyl, W A; Schalekamp, M A.
Afiliação
  • Vincent HH; Department of Internal Medicine I, Erasmus University Rotterdam, The Netherlands.
Nephrol Dial Transplant ; 5(12): 1031-7, 1990.
Article em En | MEDLINE | ID: mdl-2128952
ABSTRACT
In continuous arteriovenous haemofiltration (CAVH) or haemodiafiltration (CAVHD), it is important to obtain an adequate blood flow through the haemofilter to minimise the risk of excessive haemoconcentration and clotting. In this study we determined the resistance to blood flow of the extracorporeal device as well as the hydraulic permeability of the filter membrane is intensive care patients treated with CAVHD. Data were obtained for CAVH catheters and Scribner shunts and for a polyacrylonitrile (AN-69) plate filter, an AN-69 capillary filter and a polysulphone (PS) capillary filter. In accordance with recent literature we also predicted the resistance to flow by using Poiseuille's law and a formula for the estimation of blood viscosity. Although with all three filters an adequate blood flow was usually obtained, the resistance to blood flow was 2-3 times greater than the predicted value. With continued use of the filter, resistance to blood flow remained largely unchanged. When, in the laboratory, the AN-69 capillary filter was perfused with saline and with a viscous sucrose solution, the resistance to flow was only 1.4 time the predicted value, a difference that might result from small deviations of the capillary diameter. When perfused with blood, the resistance was 2.6 times greater than the predicted value. This was largely explained by gross underestimation of blood viscosity in these patients. By combining laboratory data on filter resistance during saline perfusion and a more accurate estimation of blood viscosity, a reasonably accurate prediction of blood flow rate would be feasible. In the clinic the hydraulic permeability of the filters decreased with time.(ABSTRACT TRUNCATED AT 250 WORDS)
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hemofiltração Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Nephrol Dial Transplant Assunto da revista: NEFROLOGIA / TRANSPLANTE Ano de publicação: 1990 Tipo de documento: Article País de afiliação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hemofiltração Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Nephrol Dial Transplant Assunto da revista: NEFROLOGIA / TRANSPLANTE Ano de publicação: 1990 Tipo de documento: Article País de afiliação: Holanda