Your browser doesn't support javascript.
loading
A preliminary comparison of total skin electron treatment techniques to demonstrate the application of a mid-torso phantom for measurement of dose penetration.
Baugh, G; Al-Alawi, T; Fletcher, C L; Mills, J A; Grieve, R J.
Afiliação
  • Baugh G; Department of Clinical Physics and Bioengineering, University Hospital, Coventry, UK. gareth.baugh@uhcw.nhs.uk
Br J Radiol ; 84(1008): 1125-30, 2011 Dec.
Article em En | MEDLINE | ID: mdl-21304004
OBJECTIVES: In the UK, the treatment of patients with mycosis fungoides using total skin electron (TSE) beam therapy is undertaken using a number of different irradiation techniques. As part of a review of these techniques, a comparative set of measurements would be useful to determine how the techniques differ in terms of dose distribution. A dose penetration intercomparison method that could be used as part of such a study is presented here. METHODS: The dose penetrations for six treatment techniques currently or recently used in four centres in the UK were measured. The variation of dose with skin depth was measured in a WT1 solid water mid-torso phantom. The phantom is portable and suitable to be used in all the techniques. It is designed to hold four small radiochromic film dosemeters to investigate the variation in dose around the mid-torso. For each treatment technique, the phantom was irradiated using the clinical set-up. RESULTS: The phantom performed well and was able to measure dose penetration and the uniformity of penetration for several treatment techniques. CONCLUSION: These preliminary results demonstrate that there is some variation in dose distribution between different TSE treatment techniques and that the phantom could be used in a more comprehensive intercomparison. The results are not intended to demonstrate comprehensively the range of penetration that can be achieved in clinical practice as, for one of the treatment techniques, the penetration is customised for the extent of the disease.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Neoplasias Cutâneas / Planejamento da Radioterapia Assistida por Computador / Micose Fungoide / Imagens de Fantasmas Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Br J Radiol Ano de publicação: 2011 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Neoplasias Cutâneas / Planejamento da Radioterapia Assistida por Computador / Micose Fungoide / Imagens de Fantasmas Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Br J Radiol Ano de publicação: 2011 Tipo de documento: Article País de publicação: Reino Unido