Your browser doesn't support javascript.
loading
Determination of triamcinolone in human plasma by a sensitive HPLC-ESI-MS/MS method: application for a pharmacokinetic study using nasal spray formulation.
César, Isabela Costa; Byrro, Ricardo Martins Duarte; de Santana e Silva Cardoso, Fabiana Fernandes; Mundim, Iram Moreira; de Souza Teixeira, Leonardo; de Sousa, Weidson Carlo; Gomes, Sandro Antônio; Bellorio, Karini Bruno; Brêtas, Juliana Machado; Pianetti, Gerson Antônio.
Afiliação
  • César IC; Instituto de Ciências Farmacêuticas, Alameda Coronel Eugênio Jardim 53, 74175-100 Goiânia, GO, Brazil. isaccesar@bol.com.br
J Mass Spectrom ; 46(3): 320-6, 2011 Mar.
Article em En | MEDLINE | ID: mdl-21394848
ABSTRACT
A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for the quantitation of triamcinolone in human plasma after nasal spray application was developed and validated. Betamethasone was used as internal standard (IS). The analytes were extracted by a liquid-liquid procedure and separated on a Zorbax Eclipse XDB C(18) column with a mobile phase composed of 2 mM aqueous ammonium acetate pH 3.2 and acetonitrile (5545). Selected reaction monitoring was performed using the transitions m/z 435 → 415 and m/z 393 → 373 to quantify triamcinolone acetonide and betamethasone, respectively. Calibration curve was constructed over the range of 20-2000 pg/ml for triamcinolone acetonide. The lower limit of quantitation was 20 pg/ml. The mean RSD values were 4.6% and 5.7% for the intra-run and inter-run precision, respectively. The mean accuracy value was 98.5% and a recovery rate corresponding to 97.5% was achieved. No matrix effect was detected in the samples. The validated method was successfully applied to determine the plasma concentrations of triamcinolone acetonide in healthy volunteers, in a pharmacokinetic study with nasal spray formulation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Triancinolona / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Mass Spectrom Assunto da revista: BIOQUIMICA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Triancinolona / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Mass Spectrom Assunto da revista: BIOQUIMICA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil