Your browser doesn't support javascript.
loading
A rapid and sensitive liquid chromatography-tandem mass spectrometry method for determination of olopatadine concentration in human plasma.
Zhu, Ping; Wen, Yu-Guan; Fan, Xiao-Ping; Zhou, Zhi-Ling; Fan, Rui-Xin; Chen, Ji-Mei; Huang, Ke-Li; Zhu, Xiao-Lan; Chen, Yan-Fang; Zhuang, Jian.
Afiliação
  • Zhu P; Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong General Hospital, and Guangdong Academy of Medical Sciences, Guangzhou 510080, China.
J Anal Toxicol ; 35(2): 113-8, 2011 Mar.
Article em En | MEDLINE | ID: mdl-21396231
ABSTRACT
A sensitive and rapid method based on liquid chromatography- tandem mass spectrometry (MS-MS) was developed for the determination of olopatadine in human plasma. Sample preparations were carried out by protein precipitation with the addition of acetonitrile followed by liquid-liquid extraction with ethyl acetate/dichloromethane after internal standard (IS, amitriptyline) spiked. After evaporation to dryness, the resultant residue was reconstituted in mobile phase. Separation of olopatadine and IS from the interferences was achieved on a C(18) column followed by MS-MS detection. The analytes were monitored in the positive ionization mode with a TurboIonspray source. Multiple reaction monitoring using the transition of m/z 338 → 165 and m/z 278 → 91 was performed to quantify olopatadine and IS, respectively. The method had a total chromatographic run time of 3.5 min and linear calibration curves over the concentration range of 0.2-100 ng/mL. The lower limit of quantification was 0.2 ng/mL. For each QC concentration level the intra- and interday precisions were less than 11.4%, and relative errors ranged between -6.40% and 9.26%. The validated method was successfully applied to the quantification of olopatadine concentration in human plasma after administration of olopatadine at an oral dose of 5 mg in order to evaluate the pharmacokinetics.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anti-Inflamatórios não Esteroides / Dibenzoxepinas Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Revista: J Anal Toxicol Ano de publicação: 2011 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anti-Inflamatórios não Esteroides / Dibenzoxepinas Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Revista: J Anal Toxicol Ano de publicação: 2011 Tipo de documento: Article País de afiliação: China