Your browser doesn't support javascript.
loading
Impact of analyzing fewer image frames per segment during offline volumetric radiofrequency-based intravascular ultrasound measurements of target lesions prior to percutaneous coronary interventions.
Huisman, Jennifer; Hartmann, Marc; Mintz, Gary S; van Houwelingen, Gert K; Stoel, Martin G; de Man, Frits H A F; Louwerenburg, Hans W; von Birgelen, Clemens.
Afiliação
  • Huisman J; Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Haaksbergerstraat 55, 7513 ER Enschede, The Netherlands.
Int J Cardiovasc Imaging ; 28(3): 479-89, 2012 Mar.
Article em En | MEDLINE | ID: mdl-21424153
ABSTRACT
In the present study, we evaluated the impact of a 50% reduction in number of image frames (every second frame) on the analysis time and variability of offline volumetric radiofrequency-based intravascular ultrasound (RF-IVUS) measurements in target lesions prior to percutaneous coronary interventions (PCI). Volumetric RF-IVUS data of vessel geometry and plaque composition are generally obtained by a semi-automated analysis process that includes time-consuming manual contour editing. A reduction in the number of frames used for volumetric analysis may speed up the analysis, but could increase measurement variability. We repeatedly performed offline volumetric analyses in RF-IVUS image sets of 20 mm-long coronary segments that contained 30 de novo lesions prior to PCI. A 50% reduction in frames decreased the analysis time significantly (from 57.5 ± 7.3 to 35.7 ± 3.7 min; P < 0.0001) while geometric and compositional RF-IVUS measurements did not differ significantly from measurements obtained from all frames. The variability between measurements on the reduced number of frames versus all frames was comparable to the intra-observer measurement variability. In target lesions prior to PCI, offline volumetric RF-IVUS analyses can be performed using a reduced number of image frames (every second frame). This reduces the time of analysis without substantially increasing measurement variability.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Processamento de Imagem Assistida por Computador / Angioplastia Coronária com Balão / Ultrassonografia de Intervenção / Vasos Coronários Tipo de estudo: Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Processamento de Imagem Assistida por Computador / Angioplastia Coronária com Balão / Ultrassonografia de Intervenção / Vasos Coronários Tipo de estudo: Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Holanda
...