Target heart rate to determine the normal value of coronary flow reserve during dobutamine stress echocardiography.
Forte, Ezequiel H; Rousse, Maria G; Lowenstein, Jorge A.
Afiliação
  • Forte EH; Investigaciones Médicas, Buenos Aires, Argentina. ezeforte@yahoo.com
Cardiovasc Ultrasound ; 9: 10, 2011 Apr 04.
Article em En | MEDLINE | ID: mdl-21457582
ABSTRACT

BACKGROUND:

The determination of coronary flow reserve (CFR) is an essential concept at the moment of decision-making in ischemic heart disease. There are several direct and indirect tests to evaluate this parameter. In this sense, dobutamine stress echocardiography is one of the pharmacological method most commonly used worldwide. It has been previously demonstrated that CFR can be determined by this technique. Despite our wide experience with dobutamine stress echocardiography, we ignored the necessary heart rate to consider sufficient the test for the analysis of CFR. For this reason, our main goal was to determine the velocity of coronary flow in each stage of dobutamine stress echocardiography and the heart rate value necessary to double the baseline values of coronary flow velocity in the territory of the left anterior descending (LAD) coronary artery.

METHODS:

A total of 33 consecutive patients were analyzed. The patients included had low risk for coronary artery disease. All the participants underwent dobutamine stress echocardiography and coronary artery flow velocity was evaluated in the distal segment of LAD coronary artery using transthoracic color-Doppler echocardiography.

RESULTS:

The feasibility of determining CFR in the territory of the LAD during dobutamine stress echocardiography was high 31/33 patients (94%). Mean CFR was 2.67 at de end of dobutamine test.There was an excellent concordance between delta HR (difference between baseline HR and maximum HR) and the increase in the CFR (correlation coefficient 0.84). In this sense, we found that when HR increased by 50 beats, CFR was ≥ 2 (CI 93-99.2%). In addition, 96.4% of patients reached a CFR ≥ 2 (IC 91.1 - 99%) at 75% of their predicted maximum heart rate.

CONCLUSIONS:

We found that the feasibility of dobutamine stress echocardiography to determine CFR in the territory of the LAD coronary artery was high. In this study, it was necessary to achieve a difference of 50 bpm from baseline HR or at least 75% of the maximum predicted heart rate to consider sufficient the test for the analysis of CFR.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Reperfusão Miocárdica / Diagnóstico por Computador / Dobutamina / Eletrocardiografia / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Ultrasound Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Argentina País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Reperfusão Miocárdica / Diagnóstico por Computador / Dobutamina / Eletrocardiografia / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Ultrasound Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Argentina País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM