Your browser doesn't support javascript.
loading
A novel method for incorporating respiratory-matched attenuation correction in the motion correction of cardiac PET-CT studies.
McQuaid, Sarah J; Lambrou, Tryphon; Hutton, Brian F.
Afiliação
  • McQuaid SJ; Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA. smcquaid@bwh.harvard.edu
Phys Med Biol ; 56(10): 2903-15, 2011 May 21.
Article em En | MEDLINE | ID: mdl-21490383
ABSTRACT
Mismatches between PET and CT datasets due to respiratory effects can lead to artefactual perfusion defects. To overcome this, we have proposed a method of aligning a single CT with each frame of a gated PET study in a semi-automatic manner, incorporating a statistical shape model of the diaphragm and a rigid registration of the heart. This ensures that the structures that could influence the appearance of the reconstructed cardiac activity are correctly matched between emission and transmission datasets. When tested on two patient studies, it was found in both cases that attenuation correction using the proposed technique resulted in PET images that were closer to the gold standard of attenuation correction with a gated CT, compared with scenarios where only heart matching was considered (and not the diaphragm) or where no transformation was performed (i.e. where a single CT frame was used to attenuation-correct all PET frames). These preliminary results suggest that diaphragm matching between PET and CT improves the quantitative accuracy of reconstructed PET images and that the proposed method of using a statistical shape model to describe the diaphragm shape and motion, in combination with a rigid registration to determine respiratory-induced heart motion, is a feasible method of achieving this.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X / Tomografia por Emissão de Pósitrons / Coração / Movimento Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X / Tomografia por Emissão de Pósitrons / Coração / Movimento Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos