Your browser doesn't support javascript.
loading
Structural health monitoring using polymer-based capacitive micromachined ultrasonic transducers (CMUTs).
Hutchins, D A; Billson, D R; Bradley, R J; Ho, K S.
Afiliação
  • Hutchins DA; School of Engineering, University of Warwick, Coventry, United Kingdom. D.A.Hutchins@warwick.ac.uk
Ultrasonics ; 51(8): 870-7, 2011 Dec.
Article em En | MEDLINE | ID: mdl-21624626
ABSTRACT
Transducers based on a capacitive micromachined ultrasonic transducer (CMUT) design have been fabricated using a rapid prototyping technique. This results in a device that is constructed principally from polymers, in a process which is simple and inexpensive. The resultant devices can be attached to the surfaces of solids. Their peak sensitivity is in the 80-100 kHz range, making them ideal for applications such as acoustic emission and structural health monitoring. Good low frequency sensitivity leads to applications in vibration monitoring.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transdutores / Ultrassom / Desenho Assistido por Computador Idioma: En Revista: Ultrasonics Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transdutores / Ultrassom / Desenho Assistido por Computador Idioma: En Revista: Ultrasonics Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Reino Unido