Your browser doesn't support javascript.
loading
Effect of position and weight force on inferior vena cava diameter--implications for arrest-related death.
Ho, Jeffrey D; Dawes, Donald M; Moore, Johanna C; Caroon, Liberty V; Miner, James R.
Afiliação
  • Ho JD; Department of Emergency Medicine, Hennepin County Medical Center, 701 Park Avenue South, Minneapolis, MN 55415, United States.
Forensic Sci Int ; 212(1-3): 256-9, 2011 Oct 10.
Article em En | MEDLINE | ID: mdl-21798678
ABSTRACT

INTRODUCTION:

The physiology of many sudden, unexpected arrest-related deaths (ARDs) proximate to restraint has not been elucidated. A sudden decrease in central venous return during restraint procedures could be physiologically detrimental. The impact of body position and applied weight force on central venous return has not been previously studied. In this study, we use ultrasound to measure the size of the inferior vena cava (IVC) as a surrogate of central venous return in the standing position, prone position, and with weight force applied to the thorax in the prone position.

METHODS:

This was a prospective, observational study of volunteer human subjects. The IVC was visualized from the abdomen in both the longitudinal and transverse section in the standing and prone positions without weight force applied, and with 100 lbs (45 kg) and 147 lbs (67 kg) of weight force on the upper back in the prone position. Maximum and minimum measurements were determined in each section to account for possible respiratory variation of the IVC.

RESULTS:

The IVC significantly decreased in size with each successive change from standing to prone, from prone to prone with 100 lbs (45 kg) weight compression, from prone with 100 lbs (45 kg) weight compression to prone with 147 lbs (67 kg) weight compression (p < 0.0001). The vital sign measurements had no statistical change.

CONCLUSIONS:

The physiology involved in many sudden, unexpected ARDs has not been elucidated. However, in our study, we found a significant decrease in IVC diameter with weight force compression to the upper thorax when the subject was in the prone position. This may have implications for the tactics of restraint to aid in the prevention of sudden, unexpected ARD cases.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Cava Inferior / Causas de Morte / Suporte de Carga / Morte Súbita Cardíaca Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies Limite: Adult / Humans / Male Idioma: En Revista: Forensic Sci Int Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Cava Inferior / Causas de Morte / Suporte de Carga / Morte Súbita Cardíaca Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies Limite: Adult / Humans / Male Idioma: En Revista: Forensic Sci Int Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos