Intravascular ultrasound area strain imaging used to characterize tissue components and assess vulnerability of atherosclerotic plaques in a rabbit model.
Ultrasound Med Biol
; 37(10): 1579-87, 2011 Oct.
Article
em En
| MEDLINE
| ID: mdl-21856069
ABSTRACT
The purpose of this study was to investigate the association of area strain and tissue components and vulnerability of atherosclerotic plaques in a rabbit model. Forty purebred New Zealand rabbits underwent balloon-induced abdominal aorta endothelium injury, then a high-cholesterol diet for 24 weeks. Intravascular ultrasound (IVUS) images of abdominal aortas were acquired in situ and two consecutive frames near the end-diastole were used to construct an IVUS elastogram. Histologic slices matched with corresponding IVUS images were stained for fatty and collagen components, smooth muscle cells (SMCs) and macrophages. Regions-of-interest (ROIs) in plaques were classified as fibrous, fibro-fatty or fatty according to histologic study. Vulnerability indexes of ROIs were calculated as (fat + macrophage)/(collagen + SMCs). The area strain of these ROIs was calculated by use of an in-house-designed software system with a block-matching-based algorithm. Area strain was significantly higher in fatty ROIs (0.056 ± 0.003) than in fibrous (0.019 ± 0.002, p < 0.001) or fibro-fatty ROIs (0.033 ± 0.003, p < 0.001). The sensitivity and specificity of area strain for fatty ROIs characterization was 75.0% and 80.2% (area under the curve [AUC] 0.858, 95% confidence interval [CI] = 0.800-0.916, p < 0.001) and 75.0% and 75.3% (AUC 0.859, 95% CI = 0.801-0.917, p < 0.001) for fibrous ROIs, as demonstrated by receiver operating characteristic curve analysis. Area strain was positively correlated with vulnerability index (r(2) = 0.495, p < 0.001), fatty components (r(2) = 0.332, p < 0.001) and macrophage infiltration (r(2) = 0.406, p < 0.001); and negatively correlated with collagen and SMC composition (r(2) = 0.115 and r(2) = 0.169, p < 0.001, respectively). Area strain calculation with IVUS elastography based on digital B-mode analysis is feasible and can be useful for tissue characterization and plaque vulnerability assessment.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Aorta Abdominal
/
Placa Aterosclerótica
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
Ultrasound Med Biol
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
China