Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial.
J Bone Joint Surg Am
; 93(15): 1377-84, 2011 Aug 03.
Article
em En
| MEDLINE
| ID: mdl-21915542
BACKGROUND: Optimal alignment of the prosthesis in total knee arthroplasty results in improved patient outcomes. The goal of this study was to determine the most accurate technique for component alignment in total knee arthroplasty by comparing computer-assisted surgery with two conventional techniques involving use of an intramedullary guide for the femur and either an intramedullary or an extramedullary guide for the tibia. METHODS: One hundred and seven patients were randomized prior to surgery to one of three arms: computer-assisted surgery for both the femur and the tibia (the computer-assisted surgery group), intramedullary guides for both the femur and the tibia (the intramedullary guide group), and an intramedullary guide for the femur and an extramedullary guide for the tibia (the extramedullary guide group). Measurements of alignment on hip-to-ankle radiographs and computed tomography (CT) scans made three months after surgery were evaluated. The operative times and complications were compared among the three groups. RESULTS: The coronal tibiofemoral angle demonstrated, on average, less malalignment in the computer-assisted surgery group (1.91°) than in the extramedullary (3.22°) and intramedullary (2.59°) groups (p = 0.007). The coronal tibiofemoral angle was >3° of varus or valgus deviation in 19% (seven) of the thirty-six patients treated with computer-assisted surgery compared with 38% (thirteen) of the thirty-four in the extramedullary guide group and 36% (thirteen) of the thirty-six in the intramedullary guide group (p = 0.022). The increase in accuracy with computer-assisted surgery came at a cost of increased operative time. The operative time for the computer-assisted surgery group averaged 107 minutes compared with eighty-three and eighty minutes, respectively, for the surgery with the extramedullary and intramedullary guides (p < 0.0001). There was no significant difference in any of the outcomes between the intramedullary and extramedullary guide groups. CONCLUSIONS: This study provides evidence that the implant alignment with computer-assisted total knee arthroplasty, as measured with radiography and computed tomography, is significantly improved compared with that associated with conventional surgery with intramedullary or extramedullary guides. This finding adds to the body of evidence showing an improved radiographic outcome with computer-assisted surgery compared with that following conventional total knee arthroplasty.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ajuste de Prótese
/
Artroplastia do Joelho
/
Osteoartrite do Joelho
/
Cirurgia Assistida por Computador
/
Prótese do Joelho
Tipo de estudo:
Clinical_trials
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Female
/
Humans
/
Male
Idioma:
En
Revista:
J Bone Joint Surg Am
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
Austrália
País de publicação:
Estados Unidos