Fall algorithm development using kinematic parameters measured from simulated falls performed in a quasi-realistic environment using accelerometry.
Bourke, Alan K; Torrent, Marc; Parra, Xavier; Català, Andreu; Nelson, John.
Afiliação
  • Bourke AK; Department of Electronic and Computer Engineering, Faculty of Science and Engineering, University of Limerick, Ireland. alan.bourke@ul.ie
Article em En | MEDLINE | ID: mdl-22255326
This study aims to determine the optimal temporal, angular and acceleration parameters and thresholds for an accelerometer based, chest-worn, fall detection algorithm. In total, 10 healthy male subjects performed 14 different fall types, 3 times by each. The falls were performed onto in a quasi-realistic environment consisting of mats of a minimum thickness. Optimum parameters for; t(falling): time-to-fall, θ(max): max-angle, t(θmax) : max-angle-time, t(RTStanding) : Return-to-standing-time and t(lying) : lying-time were determined using a data set consisting of a total of 420 falls.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acidentes por Quedas / Algoritmos Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Annu Int Conf IEEE Eng Med Biol Soc Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Irlanda País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acidentes por Quedas / Algoritmos Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Annu Int Conf IEEE Eng Med Biol Soc Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Irlanda País de publicação: Estados Unidos