Your browser doesn't support javascript.
loading
Evaluation of two antibodies against double-stranded DNA assays in discriminating between active and non-active systemic lupus erythematosus: correlation between the cut-off and the specificity.
Martin, J; Durant, C; Rimbert, M; Hemont, C; Hamidou, M; Audrain, M.
Afiliação
  • Martin J; Laboratoire d'immunologie, CHU de Nantes, 5 allée de l'Île-Gloriette, Nantes, France. jer.martin@yahoo.fr
Pathol Biol (Paris) ; 60(6): 387-91, 2012 Dec.
Article em En | MEDLINE | ID: mdl-22265124
This study aimed to evaluate, improve and compare the performances of two anti-double-stranded DNA (dsDNA) detection kits, differing by their affinity, in discriminating between active and non-active systemic lupus erythematosus (SLE). Eighty-two anti-nuclear antibody positive sera (45 patients) were tested by two anti-dsDNA commercial quantitative assays (Fidis™, Farrzyme™). All the patients fulfilled at least four of the revised American College of Rheumatology criteria. SLE disease activity was assessed using a modified SLEDAI to remove anti-dsDNA descriptors. When using the manufacturers' cut-offs, no difference in the frequency of positive results was found with respect to disease activity, with Fidis™. On the contrary, with Farrzyme™, a significantly higher frequency of positive sera was found in active SLE patients. Nonetheless, poor performances were observed for both tests. With thresholds defined by ROC methodology, 212IU/mL for Fidis™ (Se: 83.9%, Sp: 86.3%), and 68.8IU/mL for Farrzyme (Se: 71.0%, Sp: 96.1%), a great improvement of the accuracy of the two methods was observed. Moreover, the better specificity and pLR, obtained after optimization of the Farrzyme™ test, could also be obtained with the Fidis™ assay by using a higher threshold than that obtained after optimization of the test. We concluded that when using manufacturers' cut-offs, the two assays appeared to be of poor clinical usefulness in the determination of disease activity. A great improvement was observed using higher thresholds. Moreover, a good concordance could be observed between the two assays (κ=0.764).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA / Imunoensaio / Lúpus Eritematoso Sistêmico / Anticorpos Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Pathol Biol (Paris) Ano de publicação: 2012 Tipo de documento: Article País de afiliação: França País de publicação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA / Imunoensaio / Lúpus Eritematoso Sistêmico / Anticorpos Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Pathol Biol (Paris) Ano de publicação: 2012 Tipo de documento: Article País de afiliação: França País de publicação: França