Union of an intra-articular distal radius fracture after successive failures of three locking plates: a case report.
Khan, S K; Gozzard, C.
Afiliação
  • Khan SK; Department of Trauma and Orthopaedics, Derriford Hospital, Plymouth, PL6 8DH, UK, Sameer.khan@doctors.net.uk.
Strategies Trauma Limb Reconstr ; 7(1): 45-50, 2012 Apr.
Article em En | MEDLINE | ID: mdl-22278597
We report a case of a 30-year old male, who presented with a right distal radius intra-articular fracture complicated by compartment syndrome. He was treated with fasciotomies and fracture fixation with a 3.5 mm LCP (Synthes(™)), followed 7 days later by skin graft. Repeat radiographs 8 weeks later showed a break across the plate at the level of an unfilled screw hole over the fracture. He underwent exchange plating with a 2.4 mm LCP Distal Radius Plate (Synthes(™)). This revision was complicated by an infected wound dehiscence 2 weeks later requiring multiple procedures. Radiographs at 20 weeks showed broken distal screws. A second revision was performed. At 12 months, the fracture had healed clinically and radiologically, but the three distal screws had broken. We discuss the multifactorial failures of the these three attempts at osteosynthesis, and which factors helped achieve osseous union. We also discuss the literature on volar locking plate breakage and conclude with the recommendations to avoid this rare complication.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Strategies Trauma Limb Reconstr Ano de publicação: 2012 Tipo de documento: Article País de publicação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Strategies Trauma Limb Reconstr Ano de publicação: 2012 Tipo de documento: Article País de publicação: Índia