Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry.
Vaccaro, Calogero; Busetto, Roberto; Bernardini, Daniele; Anselmi, Carlo; Zotti, Alessandro.
Afiliação
  • Vaccaro C; Department of Veterinary Clinical Sciences, Radiology Unit, Faculty of Veterinary Medicine, University of Padua, 35020 Legnaro (PD), Italy.
Am J Vet Res ; 73(3): 381-4, 2012 Mar.
Article em En | MEDLINE | ID: mdl-22369530
OBJECTIVE: To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). SAMPLE: Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. PROCEDURES: Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specimen was subsequently scanned by use of the same DEXA equipment. The BMD values resulting from each DEXA scan were paired with the MGVs obtained by use of software on the corresponding digitalized or digital radiographic image. RESULTS: The MGV analysis of digitalized and digital x-ray images was a precise (coefficient of variation, 0.1 and 0.09, respectively) and highly accurate method for assessing BMD, compared with DEXA (correlation coefficient, 0.910 and 0.937 for conventional and digital radiography, respectively). CONCLUSIONS AND CLINICAL RELEVANCE: The high correlation between MGV and BMD indicated that MGV analysis may be a reliable alternative to DEXA in assessing radiographic bone density. This may provide a new, inexpensive, and readily available estimate of BMD.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bovinos / Ossos do Metatarso / Interpretação de Imagem Radiográfica Assistida por Computador / Densidade Óssea / Cavalos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Animals Idioma: En Revista: Am J Vet Res Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bovinos / Ossos do Metatarso / Interpretação de Imagem Radiográfica Assistida por Computador / Densidade Óssea / Cavalos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Animals Idioma: En Revista: Am J Vet Res Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália País de publicação: Estados Unidos