Your browser doesn't support javascript.
loading
Five-year results of a randomized clinical trial comparing a polypropylene mesh with a poliglecaprone and polypropylene composite mesh for inguinal hernioplasty.
Bury, K; Smietanski, M.
Afiliação
  • Bury K; Department of Vascular and Cardiac Surgery, Medical University of Gdansk, ul. Debinki 7, 80-211, Gdansk, Poland. kbury@gumed.edu.pl
Hernia ; 16(5): 549-53, 2012 Oct.
Article em En | MEDLINE | ID: mdl-22573261
ABSTRACT

BACKGROUND:

The aim of this study was to assess whether partially absorbable monofilament mesh could influence postoperative pain and recurrence after Lichtenstein hernioplasty over the long term.

METHODS:

Patients were randomized into two groups that were treated with lightweight (LW) or heavyweight (HW) mesh in 15 centers in Poland. A modified suture technique was used in the lightweight mesh group. Clinical examination was performed. A pain questionnaire was completed five years after the surgery.

RESULTS:

Of the 392 patients who underwent surgery, 161 (90.81 %) of 177 in the HW group and 195 (90.69 %) of 215 in the LW group were examined according to protocol, a median of 62 (range 57-66) months after hernia repair. There was no difference in the recurrence rate (1.9 % LW vs. 0.6 % HW; P = 0.493). There were 24 deaths in the follow-up period, but these had no connection to the surgery. The patients treated with LW mesh reported less pain in the early postoperative period. After five years of follow-up, the intensity and the presence of pain did not differ between groups (5 patients in the LW and 4 patients in the HW group). Average pain, (VAS score), was also similar in the LW and HW group (2.25 vs. 2.4) at the fifth year postoperatively.

CONCLUSION:

The use of partially absorbable mesh reduced postoperative pain during the short-term postoperative period. No difference in pain or recurrence rate was observed at 60 months.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dor Pós-Operatória / Poliésteres / Polipropilenos / Telas Cirúrgicas / Dioxanos / Hérnia Inguinal Tipo de estudo: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Limite: Adult / Aged / Humans / Male / Middle aged Idioma: En Revista: Hernia Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dor Pós-Operatória / Poliésteres / Polipropilenos / Telas Cirúrgicas / Dioxanos / Hérnia Inguinal Tipo de estudo: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Limite: Adult / Aged / Humans / Male / Middle aged Idioma: En Revista: Hernia Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Polônia