Your browser doesn't support javascript.
loading
Towards the development of a single-step immunosensor based on an electrochemical screen-printed electrode strip coupled with immunomagnetic beads.
Volpe, G; Sozzo, U; Piermarini, S; Delibato, E; Palleschi, G; Moscone, D.
Afiliação
  • Volpe G; Dipartimento di Scienze e Tecnologie Chimiche, Università degli Studi di Roma Tor Vergata, Rome, Italy. giulia.volpe@uniroma2.it
Anal Bioanal Chem ; 405(2-3): 655-63, 2013 Jan.
Article em En | MEDLINE | ID: mdl-22736227
ABSTRACT
This work investigates the behaviour of two alternative systems that model the crucial event involved in any ELISA test, i.e. the molecular recognition between an antigen and its specific antibody on a solid phase, and its measurement. Each approach is devised with the goal of making possible a single-step, separation and wash-free amperometric magneto-immunosensor. Magnetic particles (MBs) are used as support for the immobilization of rabbit IgGs that are recognized by the specific anti-rabbit IgG-HRP. The assay protocol is based on the use of a series of small "reservoirs" containing phosphate buffer, hydroquinone, anti-rabbit IgG-HRP and an appropriate amount of MB-rabbit IgG. After a brief incubation, the content of each "reservoir" is transferred to one of the wells of a 8-well magnetized-screen-printed electrode strip. The resulting MB-IgG-anti-IgG-HRP chain, is then concentrated on the working electrode surface for electrochemical measurement. Two different approaches to monitor this immunological reaction are investigated. The first one is based on the enzyme-channeling principle (ECP) and involves the use of a second enzyme, glucose oxidase (GOD), immobilized on the working electrode previously modified with Prussian Blue. Since the H(2)O(2) produced by GOD is the co-substrate of the HRP enzyme, glucose is added into the well and the current, generated by the residual H(2)O(2), is measured. The second, more direct, approach is performed without exploiting ECP (no GOD enzyme), by adding H(2)O(2) into the well and measuring the current generated by the HRP product on a pristine screen-printed electrode. Both approaches yielded a typical sigmoidal binding curve, illustrating the discrimination between the signal produced by the immuno-bound HRP concentrated on the electrode surface, and the background signal due to HRP in the bulk solution.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Técnicas Biossensoriais / Eletroquímica Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Técnicas Biossensoriais / Eletroquímica Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Itália