Your browser doesn't support javascript.
loading
BBB on chip: microfluidic platform to mechanically and biochemically modulate blood-brain barrier function.
Griep, L M; Wolbers, F; de Wagenaar, B; ter Braak, P M; Weksler, B B; Romero, I A; Couraud, P O; Vermes, I; van der Meer, A D; van den Berg, A.
Afiliação
  • Griep LM; BIOS, Lab on a Chip group, MESA+ Institute for Nanotechnology, University of Twente, PO Box 217, 7500 AE, Enschede, The Netherlands. l.m.griep@utwente.nl
Biomed Microdevices ; 15(1): 145-50, 2013 Feb.
Article em En | MEDLINE | ID: mdl-22955726
The blood-brain barrier (BBB) is a unique feature of the human body, preserving brain homeostasis and preventing toxic substances to enter the brain. However, in various neurodegenerative diseases, the function of the BBB is disturbed. Mechanisms of the breakdown of the BBB are incompletely understood and therefore a realistic model of the BBB is essential. We present here the smallest model of the BBB yet, using a microfluidic chip, and the immortalized human brain endothelial cell line hCMEC/D3. Barrier function is modulated both mechanically, by exposure to fluid shear stress, and biochemically, by stimulation with tumor necrosis factor alpha (TNF-α), in one single device. The device has integrated electrodes to analyze barrier tightness by measuring the transendothelial electrical resistance (TEER). We demonstrate that hCMEC/D3 cells could be cultured in the microfluidic device up to 7 days, and that these cultures showed comparable TEER values with the well-established Transwell assay, with an average (± SEM) of 36.9 Ω.cm(2) (± 0.9 Ω.cm(2)) and 28.2 Ω.cm(2) (± 1.3 Ω.cm(2)) respectively. Moreover, hCMEC/D3 cells on chip expressed the tight junction protein Zonula Occludens-1 (ZO-1) at day 4. Furthermore, shear stress positively influenced barrier tightness and increased TEER values with a factor 3, up to 120 Ω.cm(2). Subsequent addition of TNF-α decreased the TEER with a factor of 10, down to 12 Ω.cm(2). This realistic microfluidic platform of the BBB is very well suited to study barrier function in detail and evaluate drug passage to finally gain more insight into the treatment of neurodegenerative diseases.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Barreira Hematoencefálica / Técnicas Analíticas Microfluídicas / Fenômenos Mecânicos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Biomed Microdevices Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Holanda País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Barreira Hematoencefálica / Técnicas Analíticas Microfluídicas / Fenômenos Mecânicos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Biomed Microdevices Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Holanda País de publicação: Estados Unidos