Right ventricular pacing with mechanical dyssynchrony causes apoptosis interruptus and calcium mishandling.
Klug, Didier; Boule, Stephane; Wissocque, Ludivine; Montaigne, David; Marechal, Xavier; Hassoun, Sidi Mohamed; Neviere, Remi.
Afiliação
  • Klug D; EA 4484, Département de Physiologie, Université Lille 2, Faculté de Médecine de Lille, Lille, France.
Can J Cardiol ; 29(4): 510-8, 2013 Apr.
Article em En | MEDLINE | ID: mdl-23062666
ABSTRACT

BACKGROUND:

Mechanical dyssynchrony associated with rapid pacing induces cardiac cell stress and myocardial apoptotic pathway activation that has been implicated in the pathophysiology of left ventricular (LV) dysfunction. Effects of dyssynchrony per se are not fully understood. The objective of our study was to test whether ventricular dyssynchrony would elicit myocardial alterations in LV calcium handling regulation and cell survival or apoptosis signalling in right ventricular-paced swine.

METHODS:

Implantation of pacemaker was performed under anaesthesia. Endocardial bipolar screw lead was inserted into the right jugular vein and positioned either in the right atrium or at the right ventricular (RV) apex. Swine were paced at 150 beats per minute for 3 weeks.

RESULTS:

Compared with right atrial pacing, RV pacing led to abnormal LV sarcoplasmic reticulum calcium uptake (315 ± 65 vs 155 ± 55 nmol/min/mg, P < 0.05) and LV calcium-handling protein expression, ie, 35% reduction in ryanodine receptor 2, 25% decline in sarcoplasmic reticulum Ca(2+) ATPase, 70% increase in Na(+)/Ca(2+) exchanger, and 10% increase in phospholamban. RV pacing also elicited activation of LV apoptotic cascades without nuclear apoptosis. So-called interrupted apoptosis was the result of increased expression of X-linked inhibitor of apoptosis protein. Apoptosis and calcium mishandling were documented in absence of depressed heart function (ejection fraction 62 ± 8% vs 57 ± 12%, in right atrial- and RV-paced hearts, respectively, P > 0.05).

CONCLUSIONS:

Slow rate RV pacing causes mechanical dyssynchrony and profound LV alterations in both apoptotic pathways and calcium handling in the early stages of pacing-induced cardiomyopathy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estimulação Cardíaca Artificial / Cálcio / Apoptose / Miócitos Cardíacos / Frequência Cardíaca / Ventrículos do Coração / Cardiomiopatias Tipo de estudo: Etiology_studies Limite: Animals Idioma: En Revista: Can J Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estimulação Cardíaca Artificial / Cálcio / Apoptose / Miócitos Cardíacos / Frequência Cardíaca / Ventrículos do Coração / Cardiomiopatias Tipo de estudo: Etiology_studies Limite: Animals Idioma: En Revista: Can J Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: França