Your browser doesn't support javascript.
loading
Development of a liquid-chromatography tandem mass spectrometry and ultra-high-performance liquid chromatography high-resolution mass spectrometry method for the quantitative determination of zearalenone and its major metabolites in chicken and pig plasma.
De Baere, S; Osselaere, A; Devreese, M; Vanhaecke, L; De Backer, P; Croubels, S.
Afiliação
  • De Baere S; Department of Pharmacology, Toxicology and Biochemistry, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium. siegrid.debaere@ugent.be
Anal Chim Acta ; 756: 37-48, 2012 Dec 05.
Article em En | MEDLINE | ID: mdl-23176738
A sensitive and specific method for the quantitative determination of zearalenone (ZEN) and its major metabolites (α-zearalenol (α-ZEL), ß-zearalenol (ß-ZEL), α-zearalanol (α-ZAL), ß-zearalanol (ß-ZAL) and zearalanone (ZAN)) in animal plasma using liquid chromatography combined with heated electrospray ionization (h-ESI) tandem mass spectrometry (LC-MS/MS) and high-resolution Orbitrap(®) mass spectrometry ((U)HPLC-HR-MS) is presented. The sample preparation was straightforward, and consisted of a deproteinization step using acetonitrile. Chromatography was performed on a Hypersil Gold column (50 mm × 2.1 mm i.d., dp: 1.9 µm, run-time: 10 min) using 0.01% acetic acid in water (A) and acetonitrile (B) as mobile phases. Both mass spectrometers were operated in the negative h-ESI mode. The method was in-house validated for all analytes: matrix-matched calibration graphs were prepared and good linearity (r≥0.99) was achieved over the concentration range tested (0.2-200 ng mL(-1)). Limits of quantification (LOQ) in plasma were between 0.2 and 5 ng mL(-1) for all compounds. Limits of detection in plasma ranged from 0.004 to 0.070 ng mL(-1). The results for the within-day and between-day precision, expressed as relative standard deviation (RSD), fell within the maximal RSD values (within-day precision: RSD(max)=2((1-0.5logConc)) x 2/3; between-day precision: RSD(max)=2((1-0.5logConc))). The accuracy fell within -50% to +20% (concentrations <1 ng mL(-1)), -30% to +10% (concentrations between 1 and 10 ng mL(-1)) or -20% to +10% (concentrations >10 ng mL(-1)) of the theoretical concentration. The method has been successfully used for the quantitative determination of ZEN in plasma samples from broiler chickens and pigs. α-ZEL and ß-ZEL were the only metabolites that could be detected, but the concentrations were around the LOQ levels. The intact ZEN-glucuronide conjugate could be detected using the (U)HPLC-HR-MS instrument. A good correlation (r(2)=0.9979) was observed between the results for ZEN obtained with the LC-MS/MS and (U)HPLC-HR-MS instruments. The results prove the usefulness of the developed method for application in the field of toxicokinetic analysis and for exposure assessment of mycotoxins.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Zearalenona / Técnicas de Química Analítica / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Revista: Anal Chim Acta Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Bélgica País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Zearalenona / Técnicas de Química Analítica / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Revista: Anal Chim Acta Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Bélgica País de publicação: Holanda