[Clinical application of centerpiece titanium plate fixation in open door laminoplasty].
Gu, Yong-Jie; Hu, Yong; Ma, Wei-Hu; Xu, Rong-Ming; Zhao, Hong-Yong.
Afiliação
  • Gu YJ; Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China. gyj1982@hotmail.com
Zhongguo Gu Shang ; 25(9): 726-9, 2012 Sep.
Article em Zh | MEDLINE | ID: mdl-23256359
OBJECTIVE: To explore the clinical application of Centerpiece titanium plate fixation in open door laminoplasty. METHODS: From January 2009 to December 2010,25 patients with cervical spinal stenosis were treated by open door laminoplasty with Centerpiece titanium plate fixation. There were 16 males and 9 females,with a mean age of (57.2 +/- 6.7) years (ranged, 44 to75 years). There were multilevel cervical myelopathy in 8 cases, posterior longitudinal ligament ossification in 12 cases and congenital cervical spinal stenosis in 5 cases. According to Japanese Orthopedic Association (JOA) score to evaluate nerve function and calculate improvement rate. X-ray and CT were used to evaluate postoperative spinal canal enlargement and bone fusion at the hinge side. The sagittal diameter of C5 spinal canal on the lateral X-ray was measured before operation and 6 months after operation respectively, and the expansion rate of spinal canal was calculated [(postoperative sagittal diameter-preoperative sagittal diameter)/(preoperative sagittal diameter) x 100%]. RESULTS: The operative time and intraoperative blood loss were respectively (165.5 +/- 35.6) min and (325.0 +/- 75.1) ml. All patients were followed up from 6 to 18 months with an average of (7.3 +/- 3.8) months. The JOA score increased from 9.3 +/- 1.1 before operation to 14.7 +/- 2.1 at 6 months after operation (t = 4.12, P < 0.05), and the improvement rate was (64.5 +/- 10.2)%. Radiographic data showed spinal canal enlarged perfectly, bone fusion at hinge side and no cervical spinal stenosis was found. The sagittal diameter of C5 spinal canal improved from (9.0 +/- 1.5) mm before operation to (14.3 +/- 2.0) mm at 6 months after operation (t = 7.61, P < 0.05), and the expansion rate was (67.6 +/- 11.8)%. CONCLUSION: Clinical application of Centerpiece titanium plate fixation in open door laminoplasty is safe and effective. While vertebral plate is elevated to obtain instantly stability, at the same time, the integrity of spinal canal is also recovered.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose Espinal / Placas Ósseas / Vértebras Cervicais / Laminectomia Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Gu Shang Assunto da revista: ORTOPEDIA / TRAUMATOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: China País de publicação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose Espinal / Placas Ósseas / Vértebras Cervicais / Laminectomia Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Gu Shang Assunto da revista: ORTOPEDIA / TRAUMATOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: China País de publicação: China