Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner.
Zywiel, M G; Brandt, J-M; Overgaard, C B; Cheung, A C; Turgeon, T R; Syed, K A.
Afiliação
  • Zywiel MG; University of Toronto, Banting Institute, Division of Orthopaedic Surgery, 100 College Street Room 302, Toronto, Ontario M5G 1L5, Canada. mike@zywiel.com
Bone Joint J ; 95-B(1): 31-7, 2013 Jan.
Article em En | MEDLINE | ID: mdl-23307670
Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt-chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy.We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Falha de Prótese / Cobalto / Artroplastia de Quadril / Prótese de Quadril / Cardiomiopatias Tipo de estudo: Diagnostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Bone Joint J Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Canadá País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Falha de Prótese / Cobalto / Artroplastia de Quadril / Prótese de Quadril / Cardiomiopatias Tipo de estudo: Diagnostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Bone Joint J Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Canadá País de publicação: Reino Unido