Dose effects and image quality: is there any influence by bearing devices in whole-body computed tomography in trauma patients?
Injury
; 45(1): 170-5, 2014 Jan.
Article
em En
| MEDLINE
| ID: mdl-23332112
ABSTRACT
BACKGROUND:
Stable bearing devices are often utilized by prehospital first responders in modern management of severely injured patients. It is not known whether these devices influence radiation exposure or image quality in whole-body computed tomography (WBCT). Additionally, manufacturers currently provide no specifications concerning these criteria. This investigation analyzed the influence of nine different bearing devices on these specified criteria.METHODS:
The influence of nine different bearing devices on radiation exposure and image quality in WBCT was investigated. The dose-length-product (DLP100) was obtained through use of a CT-ionisation chamber placed in the centre of a 32 cm CT-phantom and compared with a reference value. Moreover, the results were calculated as effective dose data E (mSv). The image quality was assessed by three expert radiologists using the following scoring scale (0=no artefacts; 1=minor artefacts; 2=clearly artefacts; 3=massive artefacts).RESULTS:
Out of nine bearing devices examined, four showed significantly higher (2.5-4.5%, p<0.05) DLP100 and five showed no significant difference between DLP100 and the reference value. The image quality was classified in the categories "0", "1", "2" and "3" in 4, 3, 1 and 1 case, respectively.CONCLUSIONS:
In diagnostic producers using WBCT, bearing devices may be associated with relevant increases in radiation dose and can affect the image assessability. Some bearing devices are associated with no significant influence on radiation dose and reduction of image quality. Considering all results to get the best balance between image quality and radiation dose, aluminium and metal-free devices should be preferred.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ferimentos e Lesões
/
Interpretação de Imagem Radiográfica Assistida por Computador
/
Imagem Corporal Total
/
Posicionamento do Paciente
/
Macas
/
Tomografia Computadorizada Multidetectores
Tipo de estudo:
Evaluation_studies
Limite:
Humans
Idioma:
En
Revista:
Injury
Ano de publicação:
2014
Tipo de documento:
Article
País de afiliação:
Alemanha