Your browser doesn't support javascript.
loading
Safety of contrast-enhanced ultrasonography in dogs and cats: 488 cases (2002-2011).
Seiler, Gabriela S; Brown, James C; Reetz, Jennifer A; Taeymans, Olivier; Bucknoff, Melissa; Rossi, Federica; Ohlerth, Stefanie; Alder, Daniela; Rademacher, Nathalie; Drost, Wm Tod; Pollard, Rachel E; Travetti, Olga; Pey, Pascaline; Saunders, Jimmy H; Shanaman, Miriam M; Oliveira, Cintia R; O'Brien, Robert T; Gaschen, Lorrie.
Afiliação
  • Seiler GS; Department of Molecular Biomedical Science, College of Veterinary Medicine, North Carolina State University, Raleigh, NC 27695, USA. gsseiler@ncsu.edu
J Am Vet Med Assoc ; 242(9): 1255-9, 2013 May 01.
Article em En | MEDLINE | ID: mdl-23600783
OBJECTIVE: To determine the incidence of adverse events within 24 hours after contrast-enhanced ultrasonography (CEUS) in dogs and cats and compare the risk of death within 24 hours after imaging for animals that underwent ultrasonography with and without injection of a contrast agent. DESIGN: Retrospective case-control study. ANIMALS: 750 animals (411 case dogs, 238 control dogs, 77 case cats, and 24 control cats). PROCEDURES: At 11 institutions, medical records were reviewed of dogs and cats that had CEUS performed (cases) as were medical records of dogs and cats with clinical signs similar to those of case animals that had ultrasonography performed without injection of a contrast agent (controls). Information regarding signalment; preexisting disease; type, dose, and administration route of contrast agent used; immediate (within 1 hour after CEUS) and delayed (> 1 and ≤ 24 hours after CEUS) adverse events; and occurrence and cause of death (when available) was extracted from each medical record. Risk of death within 24 hours after ultrasonography was compared between case and control animals. RESULTS: Of the 411 case dogs, 3 had immediate adverse events (vomiting or syncope) and 1 had a delayed adverse event (vomiting). No adverse events were recorded for case cats. Twenty-three of 357 (6.4%) clinically ill case animals and 14 of 262 (5.3%) clinically ill control animals died within 24 hours after ultrasonography; risk of death did not differ between cases and controls. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that CEUS was safe in dogs and cats.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças do Gato / Ultrassonografia / Meios de Contraste / Doenças do Cão Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: J Am Vet Med Assoc Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças do Gato / Ultrassonografia / Meios de Contraste / Doenças do Cão Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: J Am Vet Med Assoc Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos